Welcome to the company ! we have many years of professional experience !
rsdgj@pyzyrsd.com +86 513525609655

Acid industrial wastewater was used in a factory

Established in 2001, Puyang Zhong Yuan Restar Petroleum Equipment Co.,Ltd, “RSD” for short, is Henan’s high-tech enterprise with intellectual property advantages and independent legal person qualification. With registered capital of RMB 50 million, the Company has two subsidiaries-Henan Restar Separation Equipment Technology Co., Ltd We are mainly specialized in R&D, production and service of various intelligent separation and control systems in oil&gas drilling,engineering environmental protection and mining industries.We always take the lead in Chinese market shares of drilling fluid shale shaker for many years. Our products have been exported more than 20 countries and always extensively praised by customers. We are Class I network supplier of Sinopec,CNPC and CNOOC and registered supplier of ONGC, OIL India,KOC. High quality and international standard products make us gain many Large-scale drilling fluids recycling systems for Saudi Aramco and Gazprom projects.

Certificate of Honor

Get in touch with us

We will confidentially process your data and will not pass it on to a third party.

Acid industrial wastewater was used in a factory
Chromium in Drinking Water - Canada.ca
Chromium in Drinking Water - Canada.ca

Dermal absorption of Cr(VI) was also assessed in vivo with four human volunteers immersed in a bath containing 22 mg Cr(VI)/L (as ,potassium dichromate,) for 3 hours (Paustenbach et al., 2003). Dermal penetration was estimated to be < 10% of daily ingestion of water, based on blood and urine samples.

VICAIRE - Module 2 - Chapter 6
VICAIRE - Module 2 - Chapter 6

The chemical oxidant selected for the COD test is ,potassium dichromate, (K 2 Cr 2 O 7). The sample is oxidized by a boiling mixture of K 2 Cr 2 O 7 and sulfuric ,acid, using an excess of K 2 Cr 2 O 7 . After digestion, the remaining unreduced K 2 Cr 2 O 7 is measured to determine the amount consumed by titration with ferrous ammonia sulfate (FAS) until the end point is indicated by sharp colour ...

Taking a Close Look at the Pollutant | California Water ...
Taking a Close Look at the Pollutant | California Water ...

The pollutants found in the coating may be chromium (from chromate salts) such as sodium or ,potassium dichromate,, or acidic solutions (low pH) from phosphoric ,acid contained, in proprietary chemicals or toxic organics from passivation, and coloring …

Adsorption of Chromium from Aqueous Solution by ...
Adsorption of Chromium from Aqueous Solution by ...

Potassium dichromate, (K 2 Cr 2 O 7), ,Potassium, iodide (KI)(1 M), Sodium thio-sulphate (Na 2 S 2 O 3) (1M), 1N and 0.1N Hydrochloric ,acid, (HCl), starch solution, Sodium hydroxide NaOH (1M), Pinus palustris seeds 2.2 Methodology The sample Pinus palustris seeds (Figure 1) was collected from Chennai and thoroughly washed using tap water.

Guidelines for Canadian Drinking Water Quality: Guideline ...
Guidelines for Canadian Drinking Water Quality: Guideline ...

Dermal absorption of Cr(VI) was also assessed in vivo with four human volunteers immersed in a bath containing 22 mg Cr(VI)/L (as ,potassium dichromate,) for 3 hours (Paustenbach et al., 2003). Dermal penetration was estimated to be < 10% of daily ingestion of water, based on blood and urine samples.

Adsorption of Cr (VI) Onto Low-Cost Adsorbent Developed ...
Adsorption of Cr (VI) Onto Low-Cost Adsorbent Developed ...

2.8287g of 99.9% ,potassium dichromate, (K2Cr2O7) in 1000 mL of distilled water. This solution was diluted as required to obtain standard solutions containing 50-200 mg/L of Cr(VI). pH adjustment is carried out by using 0.5N HCl and 0.5N NaOH solutions. 2.3 Adsorption and kinetic studies All the adsorption experiments were performed by the batch

Adsorption of Chromium from Aqueous Solution by ...
Adsorption of Chromium from Aqueous Solution by ...

Potassium dichromate, (K 2 Cr 2 O 7), ,Potassium, iodide (KI)(1 M), Sodium thio-sulphate (Na 2 S 2 O 3) (1M), 1N and 0.1N Hydrochloric ,acid, (HCl), starch solution, Sodium hydroxide NaOH (1M), Pinus palustris seeds 2.2 Methodology The sample Pinus palustris seeds (Figure 1) was collected from Chennai and thoroughly washed using tap water.

D6HHGVDV$/RZ &RVW6RUEHQWIRU5HPRYLQJ&U 9 IURP7KH ...
D6HHGVDV$/RZ &RVW6RUEHQWIRU5HPRYLQJ&U 9 IURP7KH ...

Potassium dichromate, (K 2 Cr 2 O 7) AR grade was used for the preparation of Cr (VI) standard solutions stock in distilled water. For pH adjustment throughout the experiment, 0.1 M hydrochloric ,acid, (HCl) and/or 0.1 M sodium hydroxide (NaOH) were added. The measurement of Cr (VI) concentration using ultraviolet-visible spectrophotometer (UV-vis) by

ASSESSMENT OF HEAVY METALS IN MUNICIPAL SEWAGE …
ASSESSMENT OF HEAVY METALS IN MUNICIPAL SEWAGE …

Sludge is a waste product generated at the end of municipal and industrial ,wastewater, ... valuable nutrients ,contained, in the sludge is becoming a key issue across the globe (Lau et al., K.L. Prakash, ... 0.3 gm of sample was taken and 10 ml of 1N ,potassium dichromate, was added and followed by 20 ml concentrated sulphuric ,acid,.

Molecules | Free Full-Text | Effective Removal of Cyanide ...
Molecules | Free Full-Text | Effective Removal of Cyanide ...

A real ,electroplating wastewater,, containing 51,190 mg/L of free cyanide (CNf), 4899 mg/L of Ni and 1904 mg/L of Cu, was treated with calcium alginate hydrogel beads (CAB), pure or impregnated with biodegraded grape marc (EBGM) or activated carbon (EAC) in order to reduce the elevated load of toxic pollutants below the regulatory limits. It was evaluated the effect of increasing the amount of ...

Change Hexavalent to trivalent chrome at high pH using ...
Change Hexavalent to trivalent chrome at high pH using ...

8/8/2009, · High sulfates in ,wastewater, after chrome treatment January 30, 2018. Q. I am working in effluent treatment ,plant,, this ,plant, is designed to treat chrome water from chrome plating ,plant,. We are facing a problem of high sulphate content (>1500 ppm) in ETP product water. shahrukh ahmed - …

Adsorption of Cr(VI) from Aqueous Solution onto a ...
Adsorption of Cr(VI) from Aqueous Solution onto a ...

wastewater, include reduction followed by chemical precipitation [8,9]. Advances in water and ,wastewater, treatment technology need spur for the development of technologies that may be more effective and less costly. In general, a wide range of processes have been reported to eliminate the Cr(VI) from water and ,wastewater, such as chemical

How we get exposed to the heavy metal CHROMIUM (Cr) | Toxno
How we get exposed to the heavy metal CHROMIUM (Cr) | Toxno

Industries and processes in which exposure to chromium (VI) occurs include: production, use and welding of chromium-containing metals and alloys (e.g. stainless steels, high-chromium steels); ,electroplating,; production and use of chromium-containing compounds, such as pigments, paints (e.g. application in the aerospace industry and removal in construction and maritime industries), catalysts, chromic ,acid,…

Molecules | Free Full-Text | Effective Removal of Cyanide ...
Molecules | Free Full-Text | Effective Removal of Cyanide ...

A real ,electroplating wastewater,, containing 51,190 mg/L of free cyanide (CNf), 4899 mg/L of Ni and 1904 mg/L of Cu, was treated with calcium alginate hydrogel beads (CAB), pure or impregnated with biodegraded grape marc (EBGM) or activated carbon (EAC) in order to reduce the elevated load of toxic pollutants below the regulatory limits. It was evaluated the effect of increasing the amount of ...

Synthesis of Chitosan–Ignosulfonate Composite as an ...
Synthesis of Chitosan–Ignosulfonate Composite as an ...

The ,wastewater, from dyestuff, ,electroplating,, textile and other ... 66 g/mol, BS) were obtained from Shanghai Macklin Biochemical Co., Ltd. ,Potassium dichromate, (K 2 Cr 2 O 7, MW 294.18 ... the biosorption mechanism involved because surfaces of the copolymers ,contained, three main types of ,acid,/base sites from the amino ,acid, ...

D6HHGVDV$/RZ &RVW6RUEHQWIRU5HPRYLQJ&U 9 IURP7KH ...
D6HHGVDV$/RZ &RVW6RUEHQWIRU5HPRYLQJ&U 9 IURP7KH ...

Potassium dichromate, (K 2 Cr 2 O 7) AR grade was used for the preparation of Cr (VI) standard solutions stock in distilled water. For pH adjustment throughout the experiment, 0.1 M hydrochloric ,acid, (HCl) and/or 0.1 M sodium hydroxide (NaOH) were added. The measurement of Cr (VI) concentration using ultraviolet-visible spectrophotometer (UV-vis) by

VICAIRE - Module 2 - Chapter 6
VICAIRE - Module 2 - Chapter 6

The chemical oxidant selected for the COD test is ,potassium dichromate, (K 2 Cr 2 O 7). The sample is oxidized by a boiling mixture of K 2 Cr 2 O 7 and sulfuric ,acid, using an excess of K 2 Cr 2 O 7 . After digestion, the remaining unreduced K 2 Cr 2 O 7 is measured to determine the amount consumed by titration with ferrous ammonia sulfate (FAS) until the end point is indicated by sharp colour ...

Chat Online Inquiry Email

Business cooperation

+86 513525609655

Company address

Road West, North Branch, Jingkai Road, Puyang City